Ultrasound Med Biol ; 49(8): 1687-1698, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37121881

RESUMO

OBJECTIVE: Bone recovery typically depends on the age of organisms or the prevalence of metabolic disorders such as osteoporosis, which is a metabolic condition characterized by decreased bone strength and bone mineral density (BMD). Therefore, low-intensity pulsed ultrasound (LIPUS), a non-invasive method for osteogenic stimulation, presents promising results. However, heterogeneity in animal study designs is a typical characteristic. Hence, we conducted a systematic review to evaluate the effectiveness of LIPUS in the recovery of experimental bone defects using rat models. We examined the areal and volumetric BMD to identify LIPUS doses to be applied and evaluated the accuracy reported by previous studies. METHODS: The Virtual Health Library regional portal, PubMed, Embase, EBSCOhost, Scopus and CAPES were reviewed for animal studies that compared fracture treatments based on LIPUS with sham or no treatments using rat models and reported BMD as an outcome. The tool provided by the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE) and the Collaborative Approach to Meta-Analysis and Review of Animal Data from Experimental Studies (CAMARADES) checklist were used to assess the bias and quality of such studies. RESULTS: Of the six studies reviewed, the most frequently used LIPUS dose had an ultrasonic frequency of 1.0 MHz, repetition rate of 0.1 kHz and pulse duration of 2000 µs. An intensity (ISATA) of 30 mW/cm2 was the most preferred for bone recovery. However, the BMD could not solely irrefutably evaluate the effectiveness of LIPUS in bone recovery as the results were discordant with each other. The discrepancies in experimental methodologies, low-quality classifications and high risk of bias in the selected studies, however, did not validate the undertaking of a meta-analysis. CONCLUSION: On the basis of the BMD results, no sufficient evidence was found to recommend the use of LIPUS for bone recovery in rat models. Thus, this systematic review indicates that the accuracy of such reports must be improved to improve their scientific quality to facilitate a transition of LIPUS applications from pre-clinical research to clinic use.


Assuntos
Osteoporose , Terapia por Ultrassom , Animais , Ratos , Densidade Óssea , Consolidação da Fratura/fisiologia , Osteoporose/terapia , Terapia por Ultrassom/métodos , Ondas Ultrassônicas
2.
J Acoust Soc Am ; 152(1): 706, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35931554

RESUMO

Ultrasonic bone imaging is a complex task, primarily because of the low energy contained in the signals reflected from the internal bone structures. In this study, the reconstruction of a bone-mimicking phantom echographic image using time-domain topological energy (TDTE) is proposed. A TDTE image results from a combination of forward and adjoint fields. The first is a solution of a numerical model that reproduces the setup of the experimental data acquisition to the best extent possible. The second has similar characteristics, but the source term is the time-reversed residue between the forward field and signals obtained from the experiment. The acquisition-reconstruction system used a linear phased-array transducer with a 5 MHz center frequency to acquire the signals and was coupled with a k-wave toolbox to implement the numerical models and perform the image reconstruction. The results showed good agreement between the geometry of the real phantom and the ultrasonic images. However, thickness evaluation errors were observed, which may be due to incorrect assumptions about the velocity models throughout the medium, a priori assumed to be known. Thus, this method has shown promising results and should be applied to the real femoral neck as a long-term objective.


Assuntos
Colo do Fêmur , Transdutores , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Ultrassonografia/métodos
3.
Acta Ortop Bras ; 26(4): 255-259, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30210256

RESUMO

OBJECTIVE: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). METHODS: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). RESULTS: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. CONCLUSION: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.


OBJETIVO: Este estudo avalia a relação entre a reflexão ultrassônica e a densidade óssea de 14 amostras cilíndricas de osso cortical bovino (3,0 cm de espessura). MÉTODOS: Foi realizada a aquisição de 20 sinais de reflexão ultrassônica por amostra (passo de 2,0 mm), ao longo da superfície óssea. O Coeficiente de Reflexão Integrado (IRC) de cada sinal foi comparado por Tomografia Computadorizada Quantitativa (QCT). RESULTADOS: Sete curvas de IRC e QCT apresentaram valor de Correlação R de Pearson acima de 0,5. Para curvas de correlação fraca, QCT e IRC apresentaram tendências semelhantes em vários segmentos. CONCLUSÃO: O IRC foi sensível à variação da densidade óssea. Nível de evidência: Estudo Experimental, Investigação de Exame Diagnóstico.

4.
Acta ortop. bras ; 26(4): 255-259, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973559

RESUMO

ABSTRACT Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.


RESUMO Objetivo: Este estudo avalia a relação entre a reflexão ultrassônica e a densidade óssea de 14 amostras cilíndricas de osso cortical bovino (3,0 cm de espessura). Métodos: Foi realizada a aquisição de 20 sinais de reflexão ultrassônica por amostra (passo de 2,0 mm), ao longo da superfície óssea. O Coeficiente de Reflexão Integrado (IRC) de cada sinal foi comparado por Tomografia Computadorizada Quantitativa (QCT). Resultados: Sete curvas de IRC e QCT apresentaram valor de Correlação R de Pearson acima de 0,5. Para curvas de correlação fraca, QCT e IRC apresentaram tendências semelhantes em vários segmentos. Conclusão: O IRC foi sensível à variação da densidade óssea. Nível de evidência: Estudo Experimental, Investigação de Exame Diagnóstico.

5.
J Ther Ultrasound ; 5: 3, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28149518

RESUMO

BACKGROUND: One goal of therapeutic ultrasound is enabling heat generation in tissue. Ultrasound application protocols typically neglect these processes of absorption and backscatter/reflection at the skin/fat, fat/muscle, and muscle/bone interfaces. The aim of this study was to investigate the heating process at interfaces close to the transducer and the bone with the aid of computer simulation and tissue-mimicking materials (phantoms). METHODS: The experimental setup consists of physiotherapeutic ultrasound equipment for irradiation, two layers of soft tissue-mimicking material, and one with and one without an additional layer of bone-mimicking material. Thermocouple monitoring is used in both cases. A computational model is used with the experimental parameters in a COMSOL® software platform. RESULTS: The experimental results show significant temperature rise (42 °C) at 10 mm depth, regardless of bone layer presence, diverging 3 °C from the simulated values. The probable causes are thermocouple and transducer heating and interface reverberations. There was no statistical difference in the experimental results with and without the cortical bone for the central thermocouple of the first interface [t(38) = -1.52; 95% CI = -0.85, 0.12; p = 14]. Temperature rise (>6 °C) close to the bone layer was lower than predicted (>21 °C), possibly because without the bone layer, thermocouples at 30 mm make contact with the water bath and convection intensifies heat loss; this factor was omitted in the simulation model. CONCLUSIONS: This work suggests that more attention should be given to soft tissue layer interfaces in ultrasound therapeutic procedures even in the absence of a close bone layer.

6.
J Ther Ultrasound ; 4: 24, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27729978

RESUMO

BACKGROUND: Low-intensity physiotherapeutic ultrasound has been used in physical therapy clinics; however, there remain some scientific issues regarding the bone-healing process. The objective of this study was to investigate the influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats. METHODS: Twenty-two male adult rats were assessed quantitatively and qualitatively using radiographic, biochemical, and histological analyses. Numerical simulations were also performed. Fractures in animals in the ultrasound group (n = 11) were treated with low-intensity ultrasound (pulsed mode, duty cycle 20 %) for 10 min daily at an intensity of 40 mW/cm2 SATA (1.0 MHz) for 10 days. Fractures in animals in the control group (n = 11) were not treated. RESULTS: Alkaline phosphatase levels were non-significantly higher in the ultrasound group than in the control group in the time intervals considered (t(13) = 0.440; 95 % confidence interval (CI) -13.79 to 20.82; p = 0.67). Between-group serum calcium levels were also not significantly different (t(13) = -0.842; 95 % CI -0.48 to 0.21; p = 0.42). Finally, there were no significant differences in radiological scores between the two groups (U = 118; 95 % CI -1.99 to 1.99; p = 0.72). However, the diameter of the newly formed bone tissue was greater and more evident in the ultrasound group. CONCLUSIONS: Thirteen days after fracture, there was no significant between-group differences in bone-healing processes, although the increased alkaline phosphatase levels and diameter of new bone tissue need to be further investigated.

7.
Acta Cir Bras ; 31(1): 36-43, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26840354

RESUMO

PURPOSE: To determine the effectiveness of low-intensity therapeutic ultrasound (LITUS) on wound healing in rats with third-degree burns. METHODS: Twenty rats were divided into the Control Group that comprised four rats without third-degree burns that did not undergo LITUS, the Burned Group (BG), comprising eight rats with third-degree burns that did not undergo LITUS, and the Burned with Treatment Group (BTG), comprising eight rats with third-degree burns that were administered LITUS. LITUS began 24 h after injury and involved daily applications for 8 min at 0.1 W/cm2 for 14 days. RESULTS: The BTG lost less weight than the BG (Q=2.75; p<0.05). No visible differences were apparent among the groups' lesions on day 4. By the end of treatment, wound healing was more evident in the BTG. No statistically significant differences were found between the BG and the BTG in relation to the parameters measured using the histological changes in burn wound healing scoring system. CONCLUSION: The LITUS protocol applied to the animals with third-degree burns accelerated the formation of fibrin-leukocyte crusts and significantly reduced weight loss. However, burn wound healing was not accelerated.


Assuntos
Queimaduras/terapia , Tecido Conjuntivo/lesões , Ondas Ultrassônicas , Cicatrização , Animais , Queimaduras/classificação , Queimaduras/patologia , Fibrina/metabolismo , Temperatura Alta/efeitos adversos , Masculino , Ratos Wistar , Reepitelização , Redução de Peso
8.
Acta cir. bras ; 31(1): 36-43, Jan. 2016. graf
Artigo em Inglês | LILACS | ID: lil-771853

RESUMO

PURPOSE: To determine the effectiveness of low-intensity therapeutic ultrasound (LITUS) on wound healing in rats with third-degree burns. METHODS: Twenty rats were divided into the Control Group that comprised four rats without third-degree burns that did not undergo LITUS, the Burned Group (BG), comprising eight rats with third-degree burns that did not undergo LITUS, and the Burned with Treatment Group (BTG), comprising eight rats with third-degree burns that were administered LITUS. LITUS began 24 h after injury and involved daily applications for 8 min at 0.1 W/cm2 for 14 days. RESULTS: The BTG lost less weight than the BG (Q=2.75; p<0.05). No visible differences were apparent among the groups' lesions on day 4. By the end of treatment, wound healing was more evident in the BTG. No statistically significant differences were found between the BG and the BTG in relation to the parameters measured using the histological changes in burn wound healing scoring system. CONCLUSION: The LITUS protocol applied to the animals with third-degree burns accelerated the formation of fibrin-leukocyte crusts and significantly reduced weight loss. However, burn wound healing was not accelerated.


Assuntos
Animais , Masculino , Queimaduras/terapia , Tecido Conjuntivo/lesões , Ondas Ultrassônicas , Cicatrização , Queimaduras/classificação , Queimaduras/patologia , Fibrina/metabolismo , Temperatura Alta/efeitos adversos , Ratos Wistar , Reepitelização , Redução de Peso
9.
Sci Eng Ethics ; 22(5): 1447-1456, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26520642

RESUMO

This study focuses on retraction notices from two major Latin American/Caribbean indexing databases: SciELO and LILACS. SciELO includes open scientific journals published mostly in Latin America/the Caribbean, from which 10 % are also indexed by Thomson Reuters Web of Knowledge Journal of Citation Reports (JCR). LILACS has a similar geographical coverage and includes dissertations and conference/symposia proceedings, but it is limited to publications in the health sciences. A search for retraction notices was performed in these two databases using the keywords "retracted", "retraction" "withdrawal", "withdrawn", "removed" and "redress". Documents were manually checked to identify those that actually referred to retractions, which were then analyzed and categorized according to the reasons alleged in the notices. Dates of publication/retraction and time to retraction were also recorded. Searching procedures were performed between June and December 2014. Thirty-one retraction notices were identified, fifteen of which were in JCR-indexed journals. "Plagiarism" was alleged in six retractions of this group. Among the non-JCR journals, retraction reasons were alleged in fourteen cases, twelve of which were attributed to "plagiarism". The proportion of retracted articles for the SciELO database was approximately 0.005 %. The reasons alleged in retraction notices may be used as signposts to inform discussions in Latin America on plagiarism and research integrity. At the international level, these results suggest that the correction of the literature is becoming global and is not limited to mainstream international publications.


Assuntos
Publicações Periódicas como Assunto/ética , Publicações Periódicas como Assunto/estatística & dados numéricos , Plágio , Retratação de Publicação como Assunto , Região do Caribe , Bases de Dados Factuais/estatística & dados numéricos , Humanos , América Latina
10.
Sao Paulo Med J ; 134(1): 74-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26313116

RESUMO

CONTEXT AND OBJECTIVE: Increased frequency of retractions has recently been observed, and retractions are important events that deserve scientific investigation. This study aimed to characterize cases of retraction within general and internal medicine in a high-profile database, with interest in the country of origin of the article and the impact factor (IF) of the journal in which the retraction was made. DESIGN AND SETTING: This study consisted of reviewing retraction notes in the Thomson-Reuters Web of Knowledge (WoK) indexing database, within general and internal medicine. METHODS: The retractions were classified as plagiarism/duplication, error, fraud and authorship problems and then aggregated into two categories: "plagiarism/duplication" and "others." The countries of origin of the articles were dichotomized according to the median of the indicator "citations per paper" (CPP), and the IF was dichotomized according to its median within general and internal medicine, also obtained from the WoK database. These variables were analyzed using contingency tables according to CPP (high versus low), IF (high versus low) and period (1992-2002 versus 2003-2014). The relative risk (RR) and 95% confidence interval (CI) were estimated for plagiarism/duplication. RESULTS: A total of 86 retraction notes were identified, and retraction reasons were found for 80 of them. The probability that plagiarism/duplication was the reason for retraction was more than three times higher for the low CPP group (RR: 3.4; 95% CI: [1.9-6.2]), and similar results were seen for the IF analysis. CONCLUSION: The study identified greater incidence of plagiarism/duplication among retractions from countries with lower scientific impact.


Assuntos
Publicações Duplicadas como Assunto , Plágio , Retratação de Publicação como Assunto , Má Conduta Científica/estatística & dados numéricos , Pesquisa Biomédica/ética , Bases de Dados Bibliográficas , Humanos , Medicina Interna/ética , Fator de Impacto de Revistas , Editoração
11.
Acta ortop. bras ; 21(1): 18-22, jan.-fev. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-670851

RESUMO

Objetivo: Averiguar os possíveis efeitos do ultrassom de baixa intensidade, utilizado em tratamentos fisioterapêuticos de rotina, em fratura induzida em tíbia de ratos. Métodos: Foram utilizados 20 ratos machos Wistar , distribuídos em 2 grupos, com 10 animais, cada. No grupo ultrassom (GUS), os animais sofreram fratura óssea e tratamento com ultrassom terapêutico (UST) a 1,0 MHz e intensidade de 0,2 W/cm2, no modo pulsado a 20%, aplicado de forma estacionária, por 10 minutos, na região da fratura, durante cinco semanas. O grupo controle (GC) sofreu fratura óssea e não foi tratado com UST. Resultados: Nas radiografias, observou-se melhor consolidação no GUS em relação ao GC. Já na análise de fosfatase alcalina (FALC) e cálcio sérico (CS), não se evidenciou efeito estatisticamente significativo. Conclusão: De acordo com o presente estudo, o UST aplicado conforme esses parâmetros promoveu aceleração da consolidação, comprovada por radiografia, entretanto a análise bioquímica não foi conclusiva. Um dos motivos para essa divergência pode ter sido alguma inadequação do protocolo bioquímico, atualmente em investigação. Nível de Evidência II, Estudo prospectivo comparativo.


Objective: To analyze the possible effects of low-intensity ultrasound on induced tibia fracture of rats in a dose commonly used in physical therapy treatments. Methods: Twenty male Wistar rats were divided into two groups with 10 animals each. In the ultrasound group (USG), the animals were submitted to bone fracture and treatment with therapeutic ultrasound (TUS). Ultrasonic parameters are: frequency of 1.0 MHz, intensity of 0.2 W/cm2, pulsed mode at 20%, applied in stationary form during 10 minutes on the fracture region, for five weeks. The control group (CG) was submitted to bone fracture but not treated with ultrasound. Results: The radiographies showed better consolidation in USG compared to CG. The statistical tests for alkaline phosphatase and serum calcium did not show significant difference between groups. Conclusion: According to this study, TUS, applied with these parameters (not commonly used for bone therapy) accelerates bone healing, confirmed by radiography, yet the biochemical analysis was not conclusive. One reason for this inconsistency may have been some inadequacy of the biochemical protocol,currently under investigation. Level of Evidence II, Prospective comparative study.


Assuntos
Animais , Masculino , Consolidação da Fratura , Fraturas da Tíbia/reabilitação , Especialidade de Fisioterapia , Terapia por Ultrassom , Anestesia , Fenômenos Bioquímicos , Grupos Controle , Radiografia , Ratos Wistar , Interpretação Estatística de Dados
12.
Acta Ortop Bras ; 21(1): 18-22, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24453637

RESUMO

OBJECTIVE: To analyze the possible effects of low-intensity ultrasound on induced tibia fracture of rats in a dose commonly used in physical therapy treatments. METHODS: Twenty male Wistar rats were divided into two groups with 10 animals each. In the ultrasound group (USG), the animals were submitted to bone fracture and treatment with therapeutic ultrasound (TUS). Ultrasonic parameters are: frequency of 1.0 MHz, intensity of 0.2 W/cm2, pulsed mode at 20%, applied in stationary form during 10 minutes on the fracture region, for five weeks. The control group (CG) was submitted to bone fracture but not treated with ultrasound. RESULTS: The radiographies showed better consolidation in USG compared to CG. The statistical tests for alkaline phosphatase and serum calcium did not show significant difference between groups. CONCLUSION: According to this study, TUS, applied with these parameters (not commonly used for bone therapy) accelerates bone healing, confirmed by radiography, yet the biochemical analysis was not conclusive. One reason for this inconsistency may have been some inadequacy of the biochemical protocol, currently under investigation. Level of Evidence II, Prospective comparative study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...